Internal cement lining
The pipe shall be fabricated in compliance with AWWA C200, BS 534, BS 3601, JIS G 3457, TIS 427.
Inside cement mortar lining to AWWA C205 standard.
Outside wrapping to AWWA C203 standard.
Internal liquid epoxy
Inside painting by liquid epoxy min.406 microns DFT. to AWWA C210 standard.
Outside coating shall be coated by non-bleeding type coal tar epoxy at the minimum dry film thickness of 150 microns and topcoated by another micaceous iron oxide paint at the minimum dry film thickness of 60 microns.
MWA Standard
Inside coating shall be coated by non-bleeding type coal tar epoxy.
Outside coating shall be coated by non-bleeding type coal tar epoxy.
PWA Standard
Inside coating shall be coated by non-bleeding type coal tar epoxy at the total dry film thickness of at least 100 microns.
Outside coating shall be coated by non-bleeding type coal tar epoxy at the total dry film thickness of at least 100 microns.
Steel pipe pile for bridge Steel pipe pile for construction Steel pipe pile for landing
The pipe shall be fabricated in compliance with AWWA C200,BS 534, BS 3601, JIS G 3457, TIS 427.
Steel pipe pile advertisement
Pontoon